Loading PDF...
Pages: 2
SPECIFICATION S-240-5S-240-7.5S-240-12S-240-15S-240-24S-240-30S-240-48 MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUTVOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT SAFETY STANDARDS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSIONOTHERS NOTE PACKING OVERLOAD OVER VOLTAGE 5V7.5V12V15V24V30V48V 40A30A18A15A10A8A5A 0 ~ 40A0 ~ 30A0 ~ 18A0 ~ 15A0 ~ 10A0 ~ 8A0 ~ 5A 200W225W216W225W240W240W240W 150mVp-p200mVp-p150mVp-p150mVp-p180mVp-p180mVp-p240mVp-p 4.5 ~ 5.8V 6 ~ 9V 10 ~ 14V12 ~ 18V20 ~ 28V27 ~ 33V41 ~ 56V ±2.0%±2.0%±1.0%±1.0%±1.0%±1.0%±1.0% ±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±1.0% ±1.0%±1.0%±0.5%±0.5%±0.5%±0.5%±1.0% 1000ms, 20ms at full load 36ms at full load 47 ~ 63Hz 78%80%82%83%84%85%87% 5A/115VAC 2.5A/230VAC 15A/115VAC 30A/230VAC <2mA / 240VAC 105 ~ 135% rated output power 6 ~ 7V9.4 ~ 10.9V14.4 ~ 16.8V18.5 ~ 21.5V31.2 ~ 36V34.5 ~ 40.5V57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed. Protection type : Hiccup mode, recovers automatically after fault condition is removed. RT140FAN ON,35FAN OFF,70output shutdown≧ °C≦ °C≧ °C -10 ~ +60(Refer to output load derating curve)°C 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH°C ±°C°C0.03%/(0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes 179.3K hrs min. MIL-HDBK-217F (25)°C 190*93*65mm (L*W*H) 1.2Kg; 12pcs/15.3Kg/0.79CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. °C File Name:S-240-SPEC 2007-10-25 88 ~ 132VAC / 176 ~ 264VAC auto switch 248 ~ 370VDC FUNCTION FAN CONTROL, O.T.P. UL60950-1, TUV EN60950-1 approved (7.5V Design refer to TUV EN60950-1) HARMONIC CURRENT EMS IMMUNITY Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A 2 4 0 W Si n g l e O u t p u t Swi t c h i n g Po we r Su p p l y % % % % % % % % Auto switched 88 ~ 264VAC input Built-in passive PFC choke Protections: Short circuit / Overload / Over voltage / Over temperature Forced air cooling by built-in DC fan Built-in cooling Fan ON-OFF control LED indicator for power on Fixed switching frequency at 75KHz 2 years warranty ■Features : S - 2 4 0s e r i e s ENVIRONMENT PROTECTION EMI CONDUCTION & RADIATION SAFETY & EMC (Note 4) RIPPLE & NOISE (max.)Note.2 VOLTAGE TOLERANCENote.3 WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC ..